Description
Pressure switch 2.8–3.2 bar – spare part for Lindr
Spare pressure switch with a 2.8–3.2 bar operating range for Lindr dry coolers with a compressor. The pressure switch controls when the compressor starts and stops, and a faulty switch can cause wrong pressure or a compressor that runs too much or too little. It does not fit Profi machines. There is a separate 1–10 bar pressure switch for the Lindr K Profi.
Technical data
- Pressure range: 2.8–3.2 bar
- Fits: Lindr dry coolers with compressor (not Profi machines)
- Manufacturer: Lindr
Frequently asked questions about the Lindr pressure switch
How do I find the right pressure switch?
Check the machine model and the pressure range on the old switch. This one is 2.8–3.2 bar. If you are unsure, contact us with the model name before ordering.
Does it fit the Lindr K Profi?
No, it does not fit Profi machines. There is a separate 1–10 bar pressure switch for the Lindr K Profi.