Description
Quantor Chilly 45 M-LT glycol chiller
The Quantor Chilly 45 M-LT is a chiller unit from Quantor/Kreyer with a cooling capacity of 4.2 kW. M-LT stands for Low Temperature, and the unit supplies coolant from -10 °C to +15 °C to fermentation tanks, storage tanks and other production equipment. It is compact, space-saving and easy to install, with a hermetically sealed compressor, a coolant circuit with water tank and centrifugal pump, a stainless steel housing and a high-efficiency microchannel condenser.
Please note: This product is only available in Norway.
Made to order, shipped directly to the customer.
Features
- Coolant temperature from -10 °C to +15 °C
- Ambient temperature from +10 °C to +42 °C
- Stainless steel housing
- High-efficiency microchannel condenser
- Hermetically sealed compressor
- Coolant circuit with water tank and centrifugal pump
Applications
- Cooling must, wine, beer and other liquids such as cider, mead, carbonated soft drinks and jam during fermentation and storage
- Pre-cooling must or wine for clarification
- Stopping fermentation and tartaric stabilisation of wine
- Beer cooling, for example rapid wort chilling, conditioning, storage and cooling of a Brite Beer Tank (BBT)
- Cooling and stabilising spirits
- Temperature control in halls and storerooms (requires extra fan coil units)
The series is designed for low coolant temperatures and is well suited to cooling beer during storage and conditioning, stabilising wine and chilling before carbonation. The Chilly M-LT is competitively priced with minimal installation requirements, and suits smaller wineries, breweries and distilleries that only need cooling in production.
Technical data
- Model: Chilly 45 M-LT
- Cooling capacity: 4.2 kW (Chilly M-LT series: 2.2–4.2 kW / 2.95–5.6 HP)
- Refrigerant: R513a
- Power supply: 230 V / 1-phase / 50 Hz (other voltages on request)
- Inlet and outlet: ¾" male-thread ball valve and 13 mm hose barb for flexible hoses
Frequently asked questions about the Quantor Chilly 45 M-LT
What cooling capacity does the Chilly 45 M-LT have?
The Chilly 45 M-LT has a cooling capacity of 4.2 kW and is the largest in the Chilly M-LT series, which ranges from 2.2 to 4.2 kW.
How low a temperature can the unit deliver?
The coolant temperature can be set from -10 °C to +15 °C. Below 0 °C, the coolant must be a glycol mix that does not freeze.
What power supply does it need?
The standard is 230 V, 1-phase, 50 Hz. Other voltages are available on request.
How is it connected to the tanks?
The inlet and outlet have a ¾" male-thread ball valve and a 13 mm hose barb for flexible hoses. The coolant circulates through the cooling jacket or coil in the tank.

